WEBVTT

1
00:00:10.600 --> 00:00:15.400
So my topic for today is fluid management and hemodynamic optimization. Now

2
00:00:15.400 --> 00:00:20.800
being an intensivist, my focus would be on how we do

3
00:00:20.800 --> 00:00:25.600
it on a practical level on a day-to-day basis in the ICUs,

4
00:00:26.100 --> 00:00:31.100
of course coupled with the basic clinical assessment. The fluid management is

5
00:00:31.300 --> 00:00:35.200
is a crucial entity as far as inpatient medical care is concerned

6
00:00:35.200 --> 00:00:39.800
and every individual have their own unique and individual requirements as far

7
00:00:39.800 --> 00:00:45.200
as an IV fluid is now concerned. And there's no universal one-size

8
00:00:45.200 --> 00:00:49.800
formula, one-size-fits-formula for all the patients. Every individual will have their own

9
00:00:49.800 --> 00:00:53.400
requirement with respect to the content of the electrolytes in the fluid.

10
00:00:53.700 --> 00:00:56.500
It could be a hypotonic fluid, it could be a physiological fluid

11
00:00:56.500 --> 00:01:00.600
or it could be a starch. So different medical condition warrants different

12
00:01:00.600 --> 00:01:04.400
fluids and the volumes. So just to give an introduction about the

13
00:01:04.400 --> 00:01:08.100
type of fluid, so primarily we have two types of IV fluids,

14
00:01:08.200 --> 00:01:13.300
we all know crystalloid and colloid. The most commonly used crystalloid solutions

15
00:01:14.000 --> 00:01:18.700
in medical practice are plasmalyte. We have the lactated Ringer's solution. These

16
00:01:18.700 --> 00:01:25.000
two are considered as the physiological crystalloids

17
00:01:25.000 --> 00:01:29.100
because you know the osmolality is in power with the the pH

18
00:01:29.100 --> 00:01:32.000
of the blood. Then we have other fluids like normal saline, half

19
00:01:32.000 --> 00:01:36.900
normal saline, we have dextrose, we have dextrose normal saline in varying

20
00:01:36.900 --> 00:01:40.400
concentrations. Then comes the colloids. Colloids most commonly what we use are

21
00:01:40.400 --> 00:01:45.500
the hydroxyethyl starch solutions. Of course dextran gelatin being rarely used

22
00:01:45.600 --> 00:01:51.100
and albumin solutions depending upon whether there is a existing hypoalbuminemia

23
00:01:51.300 --> 00:01:54.800
contributing to the shock in a fluid in the patient you're assessing.

24
00:01:55.600 --> 00:02:00.300
Most commonly used fluid is the crystalloid solution which are the first-line

25
00:02:00.300 --> 00:02:05.800
treatment option. Colloid solutions may be used whenever indicated. Of

26
00:02:05.800 --> 00:02:10.000
course you should always be wary about the side effects of hypertonic

27
00:02:10.500 --> 00:02:14.900
colloid solutions, especially one of the most consistent risk factor being a

28
00:02:14.900 --> 00:02:19.200
potential risk for acute kidney injury in these patients. Now when you

29
00:02:19.200 --> 00:02:23.700
see a patient in the ICU, now often we are obsessed with

30
00:02:23.700 --> 00:02:28.400
the monitors. We all love to look at the monitors and seldom

31
00:02:28.400 --> 00:02:31.800
look at the patient in detail. So it's always a fight between

32
00:02:31.800 --> 00:02:34.800
the monitors and the patient examination with the amount of time what

33
00:02:34.800 --> 00:02:39.200
we have in assessing every patient. So patient examination is very crucial

34
00:02:39.400 --> 00:02:43.500
before diving into the parameters what you have from the lab values,

35
00:02:43.600 --> 00:02:47.100
from the monitors etc. So what are the vital signs you look

36
00:02:47.100 --> 00:02:50.900
at when you're assessing the fluid status in a patient? Body weight.

37
00:02:51.100 --> 00:02:54.500
Now patient's body weight is a very sensitive indicator of the volume

38
00:02:54.500 --> 00:02:57.700
status and it has to be taken on a daily basis, something

39
00:02:57.700 --> 00:03:00.300
which has to be done in the hospital in the ICUs. A

40
00:03:00.300 --> 00:03:02.500
daily body weight will tell you what is happening with the fluid

41
00:03:02.500 --> 00:03:07.700
status of the patient because rapid shifts in fluids will show shifts

42
00:03:07.700 --> 00:03:10.700
in the body weight of the patient. Heart rate there may be

43
00:03:10.700 --> 00:03:15.000
a tachycardia which is a normal compensatory response for a hypovolemia in

44
00:03:15.100 --> 00:03:20.100
a patient. Blood pressure, orthostatic vital signs, existing tachypnea in

45
00:03:20.100 --> 00:03:24.500
a patient would indicate a condition wherein the fluid is overloaded in

46
00:03:24.500 --> 00:03:29.300
the lung. And the most important thing is urine output. So what

47
00:03:29.300 --> 00:03:33.800
are the physical examination findings you would concentrate on are the presence

48
00:03:33.800 --> 00:03:36.700
of an edema or absence of an edema, the capillary refill time,

49
00:03:37.000 --> 00:03:40.400
look for the peripheral pulses in the patient, look for the JVP,

50
00:03:40.600 --> 00:03:44.200
skin temperature, turgor and especially in pediatric patients you look for the

51
00:03:44.200 --> 00:03:48.300
fontanelle aid, the presence of a tear when the kid cries and

52
00:03:48.300 --> 00:03:51.900
the buccal mucosa membrane and the conjunctiva. So these are essential things

53
00:03:51.900 --> 00:03:54.200
which has to be done on a daily basis whenever you are

54
00:03:54.400 --> 00:03:59.100
seeing a patient in the ward or in the ICU. We all

55
00:03:59.100 --> 00:04:02.400
know that there is a general formula called as the Holliday and

56
00:04:02.400 --> 00:04:06.200
Segar's formula which is basically the 4-2-1 rule what we follow in

57
00:04:06.800 --> 00:04:12.000
replenishing the maintenance IV fluid for a patient wherein

58
00:04:12.000 --> 00:04:14.400
the it goes like this for the first 10 kg it is

59
00:04:14.400 --> 00:04:18.200
4 ml per kg per hour and subsequent 10 kg it comes

60
00:04:18.200 --> 00:04:21.300
down by a factor of 2 ml per kg per hour. And

61
00:04:21.300 --> 00:04:23.900
any remaining weight more than 20 kg is 1 ml per kg

62
00:04:23.900 --> 00:04:26.400
per hour. This is the most commonly used formulae in the hospital

63
00:04:26.700 --> 00:04:28.700
or in a nutshell for the first 10 kg it is 100

64
00:04:28.700 --> 00:04:32.200
ml per kg per day. And for the subsequent 10 kg it

65
00:04:32.200 --> 00:04:34.600
is an additional 50 ml per kg per day and any remaining

66
00:04:34.600 --> 00:04:37.300
weight exceeding 20 kg it would be 20 ml per kg per

67
00:04:37.300 --> 00:04:40.700
day. So what is fluid responsiveness? You give a fluid to a

68
00:04:40.700 --> 00:04:45.700
patient. How does the patient's body or the circulatory system behave for

69
00:04:45.700 --> 00:04:50.500
that fluid bolus water administering to the patient? So it's basically defined

70
00:04:50.500 --> 00:04:53.500
as an index increase in the cardiac index or the cardiac output

71
00:04:53.700 --> 00:04:57.400
after you infuse a given amount of volume of either a crystalloid

72
00:04:57.400 --> 00:05:01.800
or a colloid. Now how do you take this response? Every time

73
00:05:01.800 --> 00:05:05.700
you see a response, it doesn't mean that the patient needs fluid.

74
00:05:05.800 --> 00:05:09.400
So there are subtle things to look for to exactly pinpoint as

75
00:05:09.400 --> 00:05:12.100
to whether the patient is requiring the fluid even if there is

76
00:05:12.100 --> 00:05:16.700
a fluid responsiveness or the patient doesn't require that fluid. Now fluid

77
00:05:16.700 --> 00:05:19.900
therapy is very crucial, you know it is you know in simple

78
00:05:20.000 --> 00:05:22.400
terms it is the right amount of fluid which is to be

79
00:05:22.400 --> 00:05:27.400
given at the right time and and you choose the right type

80
00:05:27.400 --> 00:05:29.600
of fluid for the patient. You have a patient who may be

81
00:05:29.600 --> 00:05:32.500
having a hyponatremia and you don't want to be giving a fluid

82
00:05:32.500 --> 00:05:35.700
which is hypertonic or a dextrose. You want to be correcting the

83
00:05:35.700 --> 00:05:39.400
hyponatremia. You have a patient who is hypernatremia. You don't want to

84
00:05:39.400 --> 00:05:42.600
end up transfusing a lot of crystalloids or a hypertonic fluid in

85
00:05:42.700 --> 00:05:47.900
such patient. You may be trans you know giving a hypotonic

86
00:05:47.900 --> 00:05:51.000
solution like a 5% dextrose or a half normal saline such patient.

87
00:05:51.000 --> 00:05:55.000
So the most important thing in a hemodynamic resuscitation of an unstable

88
00:05:55.000 --> 00:05:58.400
critically ill patient is choosing the right fluid in the right volume.

89
00:05:59.000 --> 00:06:03.600
And this has been found to be actually known to have a

90
00:06:04.600 --> 00:06:09.600
major impact on the perioperative and the peri-ICU care of the

91
00:06:09.600 --> 00:06:13.700
patients who get admitted in the hospital. Now once the fluid gets

92
00:06:13.700 --> 00:06:18.700
into your circulatory system, it gets into your venous reservoir. Okay,

93
00:06:18.700 --> 00:06:22.700
so that becomes the preload for the patient. Now whether that fluid

94
00:06:22.700 --> 00:06:26.100
is getting delivered to the remaining part of the circulatory system depends

95
00:06:26.100 --> 00:06:29.200
upon the contractility of the heart. So there comes your cardiac index.

96
00:06:29.200 --> 00:06:32.600
What is cardiac index? It is cardiac output in terms of the

97
00:06:32.600 --> 00:06:37.300
body surface area. Okay. So there are two ventricles. Both the ventricles

98
00:06:37.300 --> 00:06:41.100
should be preload dependent. Only then whatever fluid you are giving would

99
00:06:41.100 --> 00:06:44.000
show a response and that would be the right decision for that

100
00:06:44.000 --> 00:06:48.900
patient in replenishing the fluid depletion. So you would see the scenario

101
00:06:48.900 --> 00:06:52.700
here on the left. You have a ventricle which is fairly contracting

102
00:06:52.700 --> 00:06:55.700
and the right ventricle is also fairly contracting. It is collapsing as

103
00:06:55.700 --> 00:07:00.600
well. So you would say that this heart might require fluid. But

104
00:07:00.600 --> 00:07:02.900
at the same time you look at the heart on the right

105
00:07:02.900 --> 00:07:07.500
side. It's having a fairly decreased ejection fraction and you see the

106
00:07:07.500 --> 00:07:12.600
right ventricle is basically not contracting at all. So the

107
00:07:12.600 --> 00:07:17.700
different picture of the echo, what you just saw in that

108
00:07:17.700 --> 00:07:21.800
slide would tell you how that fluid bolus would behave in that

109
00:07:21.800 --> 00:07:25.600
patient. Hence comes the gold directed fluid therapy. Now what is the

110
00:07:25.600 --> 00:07:29.000
gold directed fluid therapy is you basically make a you know informed

111
00:07:29.000 --> 00:07:35.200
a clinical decision taking a parameter and targeting it to

112
00:07:36.000 --> 00:07:39.600
basically see the response of a fluid. Now a GDT or a

113
00:07:39.600 --> 00:07:43.900
gold directed fluid therapy is proven to decrease the incidence of complications,

114
00:07:44.000 --> 00:07:46.700
the ICU and the hospital length of stay and also it is

115
00:07:46.700 --> 00:07:50.400
known to decrease the mortality. Now what what are the various clinical

116
00:07:50.400 --> 00:07:55.400
indices you look for when you are basically looking for the adequacy

117
00:07:55.400 --> 00:07:59.000
of tissue perfusions. The blood pressure is very important, the mean arterial

118
00:07:59.000 --> 00:08:02.600
pressure and the cerebral abdominal perfusion pressures. You look for the urine

119
00:08:02.600 --> 00:08:07.600
output, you look for the the general conscious state, the mentation, capillary

120
00:08:07.600 --> 00:08:12.700
refill time, skin perfusion or the skin turgor, extremities.

121
00:08:12.800 --> 00:08:16.300
Look for the blood lactate levels in your arterial blood gas, the

122
00:08:16.500 --> 00:08:20.000
the base deficit, the bicarbonate levels. The most important thing which is

123
00:08:20.000 --> 00:08:25.000
actually consistently shown to have a major impact in the

124
00:08:25.000 --> 00:08:30.300
response management is the SCVO2 levels that is the oxygen saturation

125
00:08:30.300 --> 00:08:33.300
basically what you get when you draw a blood sample from the

126
00:08:33.400 --> 00:08:36.800
venous side or the superior vena cava from your central venous line.

127
00:08:37.700 --> 00:08:41.700
Mixed venous PCO2, then there's tissue PCO2, skeletal muscle. So these are

128
00:08:41.700 --> 00:08:45.600
the various parameters which have been studied and a lot of research

129
00:08:45.600 --> 00:08:48.700
has been done. But there is no one particular I can't point

130
00:08:48.700 --> 00:08:52.000
out one particular parameter to be the best. It is always a

131
00:08:52.000 --> 00:08:57.400
collective decision of a clinical examination and multiple parameters put together

132
00:08:57.600 --> 00:09:01.100
and you basically see the response of response in the sense the

133
00:09:01.100 --> 00:09:05.800
improvement in these parameters as the patient improves after the patient is

134
00:09:05.800 --> 00:09:09.400
getting the right fluid. There are these are some scenarios what you

135
00:09:09.400 --> 00:09:11.700
can see in the ICU. You know you would have a patient

136
00:09:11.900 --> 00:09:16.800
with an acute blood loss or a body fluid loss and patients

137
00:09:16.800 --> 00:09:20.400
in the ICU for a high suspicion of septic shock. So the

138
00:09:21.100 --> 00:09:26.400
management totally differs in different scenarios. As you're transfusing

139
00:09:26.400 --> 00:09:29.800
or as you're giving any fluid to the patient's body, you know

140
00:09:30.200 --> 00:09:35.900
heart behaves differently. For example, you can see the most fundamental basis

141
00:09:36.600 --> 00:09:40.800
for any fluid therapy is the Frank-Starling curve. It's basically shows how

142
00:09:41.400 --> 00:09:45.200
the contraction enhances or the stroke volume goes up as you increase

143
00:09:45.200 --> 00:09:48.800
the preload in the patient. Now here you can see the for

144
00:09:48.800 --> 00:09:52.000
a normal heart whatever preload you give, if the heart is receptive

145
00:09:52.000 --> 00:09:55.100
for that fluid, the heart would contract and eject that fluid out

146
00:09:55.200 --> 00:09:58.000
into the circulation. But at the same time if the LV ejection

147
00:09:58.000 --> 00:10:01.700
fraction is falling, whatever preload you are giving, the challenge you are

148
00:10:01.700 --> 00:10:04.100
giving, it is not going to cause an augmentation of the cardiac

149
00:10:04.100 --> 00:10:10.200
output or increasing the the pressures. But

150
00:10:10.200 --> 00:10:12.800
it it it it it it would be more like a detrimental

151
00:10:12.800 --> 00:10:17.200
situation for the patient. So choosing the right the you know choosing

152
00:10:17.200 --> 00:10:21.100
the right fluid amount depending upon the cardiac contractility is also crucial

153
00:10:21.800 --> 00:10:26.400
when you're resuscitating a patient with fluid. Now preload is nothing but

154
00:10:26.400 --> 00:10:29.000
what you give the fluid amount of fluid which goes into the

155
00:10:29.100 --> 00:10:33.600
or the amount of blood volume which goes into the patient's ventricles

156
00:10:33.600 --> 00:10:38.700
during diastole. Now preload dependence is if the patients based on certain

157
00:10:38.700 --> 00:10:44.300
clinical signs clinical parameters you see that the patient

158
00:10:45.200 --> 00:10:49.800
can be given fluid at that particular juncture. So as you continue

159
00:10:49.800 --> 00:10:54.800
to resuscitate a patient, this graph says that the the same heart

160
00:10:54.800 --> 00:10:58.900
and the same patient you may find the patient's Frank-Starling curve at

161
00:10:58.900 --> 00:11:04.200
different levels as the fluid resuscitation is ongoing. That is

162
00:11:04.300 --> 00:11:07.100
to sum it up if the patient is initially hypovolemic, the patient

163
00:11:07.100 --> 00:11:09.500
will be receptive for the fluid. But if you continue to give

164
00:11:09.500 --> 00:11:12.400
the same fluid at the same rate for a prolonged period, then

165
00:11:12.400 --> 00:11:14.800
you may end up troubles and there can be fluid overload because

166
00:11:14.900 --> 00:11:20.000
the as the the fluid is replenished, the responsiveness keeps

167
00:11:20.000 --> 00:11:23.600
on decreasing. So the heart may be found at different stages of

168
00:11:23.600 --> 00:11:28.800
this Frank-Starling curve during resuscitation. Now

169
00:11:29.200 --> 00:11:31.800
as you give a volume to a patient, you want certain parameter

170
00:11:31.800 --> 00:11:34.600
to be seen on the monitor to assess whether this volume is

171
00:11:34.600 --> 00:11:37.700
making an impact on the outcome of the patient. Now gone are

172
00:11:37.700 --> 00:11:41.100
the days wherein we focus mainly on the static parameters. For example,

173
00:11:41.500 --> 00:11:44.400
we look always looked at the CVP as a measure to say

174
00:11:44.400 --> 00:11:47.000
okay, I'm giving an x amount of fluid to the patient and

175
00:11:47.000 --> 00:11:49.800
the patient is going to show a response. Now it has a

176
00:11:49.800 --> 00:11:53.600
lot of studies have come up wherein CVP is not found to

177
00:11:53.600 --> 00:11:56.800
be a consistent parameter to tell you that this fluid is going

178
00:11:56.800 --> 00:12:00.800
to give a major response in the patient. and it is more

179
00:12:01.300 --> 00:12:04.900
the shift has gone to the dynamic parameters like the stroke stroke

180
00:12:04.900 --> 00:12:08.400
volume variation, you know the pulse pressure variation, the systolic pressure variation,

181
00:12:08.400 --> 00:12:12.500
the IVC diameter and the passive leg raise test. So the current

182
00:12:12.500 --> 00:12:16.300
practice is all focused on the dynamic parameters than the static parameters.

183
00:12:16.700 --> 00:12:19.400
So the PAOP is basically the wedge pressure, then you have the

184
00:12:19.400 --> 00:12:24.400
RV end-diastolic volume, LV end-diastolic area, the global end-diastolic volume and intrathoracic

185
00:12:24.400 --> 00:12:26.900
blood volume. See these are basically the parameters which you look at

186
00:12:27.300 --> 00:12:29.300
at a given point of time. It will give you an x

187
00:12:29.300 --> 00:12:31.900
amount of value, but you cannot comment much based on that value.

188
00:12:31.900 --> 00:12:35.000
But here you see the trend of the variability of these parameters

189
00:12:35.200 --> 00:12:37.900
and that is found to give a better idea as to how

190
00:12:37.900 --> 00:12:41.900
the patient's circulation is behaving when the fluid is given. As I

191
00:12:41.900 --> 00:12:45.200
mentioned, there is a poor correlation between the CVP and the circulating

192
00:12:45.700 --> 00:12:50.800
blood volume. Now since time immemorial since the pulmonary artery

193
00:12:50.800 --> 00:12:54.900
catheter came into practice, it has been the gold standard modality as

194
00:12:54.900 --> 00:12:59.300
far as assessment of a fluid response is concerned and the basic

195
00:12:59.300 --> 00:13:04.200
principle what we use in PA catheter is basically thermodilution method wherein

196
00:13:04.200 --> 00:13:07.200
it could be a continuous thermodilution method by using a heating coil

197
00:13:07.400 --> 00:13:11.300
or an intermittent. So whatever fluid boluses you give, it gives a

198
00:13:11.300 --> 00:13:15.100
pretty accurate value of increasing the cardiac output or the cardiac index

199
00:13:15.300 --> 00:13:20.100
and it is found to be pretty convincing in many of these

200
00:13:20.100 --> 00:13:24.900
studies. Of course there can be errors like any monitoring techniques could

201
00:13:24.900 --> 00:13:28.500
be there could there could be a catheter malposition, the temperature of

202
00:13:28.500 --> 00:13:31.500
the injected what you use in a thermodilution method. If it is

203
00:13:31.500 --> 00:13:34.700
not consistent, then give a wrong value. Now there is another entity

204
00:13:34.700 --> 00:13:37.000
which you could derive from a pulmonary artery catheter. It's called as

205
00:13:37.000 --> 00:13:40.300
pulmonary capillary wedge pressure. So if the wedge pressure is less than

206
00:13:40.300 --> 00:13:43.600
12, it means the fluid in the left side of the heart

207
00:13:43.600 --> 00:13:46.800
is less and that heart can take fluid. But if the wedge

208
00:13:46.800 --> 00:13:49.900
pressure is increasing, it means whatever fluid you're giving to the patient

209
00:13:49.900 --> 00:13:52.600
is not going to cause a benefit, but it can cause more

210
00:13:52.600 --> 00:13:55.000
harm in the form of a pulmonary edema maybe. Then there is

211
00:13:55.000 --> 00:13:58.000
another entity called as mixed venous oxygen saturation. So basically what you're

212
00:13:58.000 --> 00:14:01.300
measuring here is you're drawing this tip of the pulmonary artery would

213
00:14:01.700 --> 00:14:04.600
the catheter would lie in the pulmonary artery. Now when you draw

214
00:14:04.600 --> 00:14:09.500
a sample from this yellow line what you're seeing here you get

215
00:14:09.500 --> 00:14:12.700
a blood sample from the pulmonary artery. This is basically a mix

216
00:14:12.700 --> 00:14:15.200
of the blood going from the superior vena cava and the inferior

217
00:14:15.200 --> 00:14:19.000
vena cava into the right side. So based on what fluid replenishment

218
00:14:19.000 --> 00:14:22.200
method you are using, any 2% rise in the value that is

219
00:14:22.200 --> 00:14:27.100
SVO2 basically the saturation of the the O2 saturation what you see

220
00:14:27.100 --> 00:14:32.200
in that mixed venous blood gas we we would suggest

221
00:14:32.200 --> 00:14:37.800
that the fluid response was adequate. Now as advancements

222
00:14:38.200 --> 00:14:41.500
came in, you know the shift has been to more of non-invasive

223
00:14:41.500 --> 00:14:45.600
methods and pulmonary artery catheter is almost becoming obsolete these days and

224
00:14:45.700 --> 00:14:49.800
a lot of non-invasive monitoring modalities have come into being. And one

225
00:14:49.800 --> 00:14:53.600
such technique is the bioimpedance technology, bioimpedance technology. This is the most

226
00:14:53.600 --> 00:14:57.600
common technology based on which these non-invasive cardiac output monitors have come

227
00:14:57.600 --> 00:15:01.800
into existence. Now one there is no particular device you can point

228
00:15:01.800 --> 00:15:04.600
out which would say that okay, this is going to give the

229
00:15:04.600 --> 00:15:07.400
best outcome for the patient. But it is an overall interpretation of

230
00:15:07.400 --> 00:15:11.200
the values what you see here. Of course parallelly looking at the

231
00:15:11.300 --> 00:15:15.300
clinical parameters, tissue hypoperfusion, lactates and the SCVO2 or the mixed venous

232
00:15:15.300 --> 00:15:19.600
saturation as I mentioned. Bioimpedance this is something which is routinely used

233
00:15:19.600 --> 00:15:24.200
most in a lot of hospitals wherein you would look for the

234
00:15:24.500 --> 00:15:28.400
change. It's basically measures the blood flow in the chest by application

235
00:15:28.400 --> 00:15:33.300
of an external electric field along the chest. They they use ECG

236
00:15:34.300 --> 00:15:39.100
leads or the electrodes placed along the chest and the neck and

237
00:15:39.800 --> 00:15:43.700
by means of the current what goes into the body from the

238
00:15:43.700 --> 00:15:47.500
device and what comes out they create an algorithm based on which

239
00:15:47.600 --> 00:15:53.100
they measure the change in the stroke volume. Now a

240
00:15:53.100 --> 00:15:57.900
10% increase is found to be a good predictor in patients who

241
00:15:57.900 --> 00:16:02.900
are volume depleted. Now using the arterial trace and the

242
00:16:02.900 --> 00:16:06.300
variables of arterial trace a lot of modalities have come into being.

243
00:16:06.700 --> 00:16:10.100
The basis of this is a principle called as heart-lung interaction that

244
00:16:10.100 --> 00:16:13.100
is a pulse pressure variation. So what is heart-lung interaction? When you

245
00:16:13.100 --> 00:16:16.600
ventilate a patient, there are two things which is happening. That is

246
00:16:16.600 --> 00:16:20.000
when your patient is having an ET tube, the there there there

247
00:16:20.000 --> 00:16:22.800
is a rise in the intrathoracic pressure and at the same time

248
00:16:22.800 --> 00:16:26.000
there is a rise in the transpulmonary pressure. Both these entities behave

249
00:16:26.000 --> 00:16:29.000
differently on the heart. An intrathoracic pressure rise would lead to a

250
00:16:29.000 --> 00:16:33.400
decreased RV preload and that would lead to basically a decrease LV

251
00:16:33.400 --> 00:16:36.900
preload and fall in the LV stroke volume. But at simultaneously there

252
00:16:36.900 --> 00:16:41.100
is always already increased transpulmonary pressure happening in these patients, the same

253
00:16:41.100 --> 00:16:44.000
patient. So that would lead to an increase in the LV preload

254
00:16:44.200 --> 00:16:46.900
and decrease LV afterload which would contribute to an LV stroke volume.

255
00:16:47.200 --> 00:16:51.300
Now this transpulmonary pressure increase is known to cause a increase in

256
00:16:51.300 --> 00:16:55.800
the pulse volume at the peak of inspiration. And the intrathoracic pressure

257
00:16:56.000 --> 00:16:59.900
with a some delay because of the blood pulmonary transit time will

258
00:16:59.900 --> 00:17:04.100
show a PP minimum at the expiration. So that transit time is

259
00:17:04.100 --> 00:17:07.300
no is the reason why as to you see the fall in

260
00:17:07.300 --> 00:17:15.500
the pulse pressure between the inspiration and the expiration. Basic

261
00:17:15.500 --> 00:17:18.800
concept of a heart-lung interaction when you see talk about fluid management

262
00:17:18.800 --> 00:17:21.800
is that it is considered as a pump within a pump. That

263
00:17:21.800 --> 00:17:24.700
is it is there are two chambers of the heart and the

264
00:17:24.700 --> 00:17:28.300
lungs on either side. They basically coexist and any change in the

265
00:17:28.300 --> 00:17:33.200
volume status in the thoracic cavity during the respiratory cycle would affect

266
00:17:33.200 --> 00:17:36.800
the performance of the heart. So this is the basic entity I

267
00:17:36.800 --> 00:17:42.300
would say which is the cornerstone whenever we talk about any non-invasive

268
00:17:42.500 --> 00:17:47.000
cardiac output monitor or the monitoring modalities based on the pulse pressure

269
00:17:47.200 --> 00:17:52.100
variation. So in pulse pressure variation technique we are basically seeing the

270
00:17:52.100 --> 00:17:55.700
variation in the pulse pressure with the respiratory cycle. Now for this

271
00:17:55.800 --> 00:18:01.400
it requires you know a sinus rhythm, a mechanical when patients who

272
00:18:01.400 --> 00:18:05.500
are totally paralyzed and without any spontaneous ventilation and a tidal volume

273
00:18:05.600 --> 00:18:08.300
at least 6 ml per kg body weight. There should be no

274
00:18:08.800 --> 00:18:13.800
RV failure, the chest should be closed and a consistent value

275
00:18:13.800 --> 00:18:16.600
of more than 12% increase in the pulse pressure variation would suggest

276
00:18:16.600 --> 00:18:21.000
the fluid responsiveness. FR stands for fluid responsiveness. Similar thing there is

277
00:18:21.000 --> 00:18:24.400
something called as pulse contour cardiac output. Basically you are assessing the

278
00:18:24.400 --> 00:18:29.600
arterial waveform trace and which is measured by various devices

279
00:18:29.600 --> 00:18:34.600
like flow track, lidco, picco etc. And the interpretation has the same

280
00:18:34.600 --> 00:18:39.300
caveats as a pulse pressure variation technique. Now optimal threshold to predict

281
00:18:39.300 --> 00:18:42.700
any pulse pressure variation technique by any device is at least 10

282
00:18:42.700 --> 00:18:47.700
to 15% change in the from the previous value. So various

283
00:18:47.700 --> 00:18:50.800
modalities what I just discussed based on the pulse pressure variation techniques

284
00:18:50.800 --> 00:18:56.100
are the picco plus, the lidco plus, EV 1000, flow track, nicom.

285
00:18:56.100 --> 00:18:59.300
So these these are the various modalities or the non-invasive monitoring techniques

286
00:18:59.300 --> 00:19:03.300
which we have been using in clinical practice and these are almost

287
00:19:03.300 --> 00:19:08.300
replacing your invasive monitoring modalities. SPV is

288
00:19:08.300 --> 00:19:13.200
a similar concept now based on the systolic pressure fluctuation with a

289
00:19:13.200 --> 00:19:16.600
spontaneous breathing. Now we all know that what is pulses paradoxes. Basically

290
00:19:16.600 --> 00:19:18.700
there is a fluctuation on the fall in BP by more than

291
00:19:18.700 --> 00:19:21.700
10 mm of mercury. Now that happens in a spontaneously breathing patient.

292
00:19:22.300 --> 00:19:24.600
In a patient on mechanical ventilation it is the other way it

293
00:19:24.600 --> 00:19:27.100
is happening because you're giving air through the ET tube. It increases

294
00:19:27.100 --> 00:19:30.800
the intrathoracic pressure and there is something called as reverse pulses paradox.

295
00:19:30.800 --> 00:19:36.000
So what pulse otherwise fell during the inspira the

296
00:19:36.000 --> 00:19:41.100
expiration will be rising during inspiration and pause during expiration

297
00:19:41.100 --> 00:19:43.500
when the patient is on mechanical ventilation. It is the other way

298
00:19:43.500 --> 00:19:49.000
around it happens when the patient is spontaneously breathing. The

299
00:19:49.000 --> 00:19:53.000
limitations as I mentioned when using any monitoring modality like picco, lidco,

300
00:19:53.000 --> 00:19:57.400
flow track are the limita the patient should be completely paralyzed. They

301
00:19:57.400 --> 00:20:01.200
should not be having any spontaneous breaths. Presence of an arrhythmia definitely

302
00:20:01.200 --> 00:20:07.000
will have some interference and may give a false positive values. Low

303
00:20:07.000 --> 00:20:10.400
tidal volume ventilation will also have a false negative values. When the

304
00:20:10.400 --> 00:20:14.300
lung compliance is low, they can show errors. Thorax is open. For

305
00:20:14.300 --> 00:20:17.200
example, you had a patient in the ICU with after an open

306
00:20:17.200 --> 00:20:19.900
thorax surgery, any surgery wherein the patient has been shifted to an

307
00:20:19.900 --> 00:20:22.900
open thorax or the conditions in the inside the OT when the

308
00:20:22.900 --> 00:20:25.900
thorax is open after a sternotomy or a thoracotomy, the reliability of

309
00:20:25.900 --> 00:20:28.900
these techniques goes down. And in conditions wherein the abdominal pressure is

310
00:20:28.900 --> 00:20:34.300
increased again the false positivity increases. So as I mentioned the advantages

311
00:20:34.300 --> 00:20:37.600
of the various advantages and disadvantages, most commonly what we use monitoring

312
00:20:37.600 --> 00:20:40.900
modality is the pulmonary artery catheter which is the gold standard. And

313
00:20:41.000 --> 00:20:44.000
based on what errors which could occur as I mentioned in the

314
00:20:44.000 --> 00:20:48.200
previous slide, the reliability can go down. So we should ensure that

315
00:20:48.200 --> 00:20:52.300
all those caveats or all those factors are taken care of. So

316
00:20:52.400 --> 00:20:55.600
one of the most commonly used modality in ICUs are lidco, picco

317
00:20:55.600 --> 00:20:59.600
and the flow track. TE often is an it's a minimally invasive

318
00:20:59.600 --> 00:21:03.400
technique. It needs some expertise. Everyone cannot do that, but these monitoring

319
00:21:03.400 --> 00:21:07.900
modalities are commonly used and basically are user-friendly and easy to interpret.

320
00:21:11.600 --> 00:21:16.600
Use of trans esophageal echo or transthoracic echo is something which is

321
00:21:16.700 --> 00:21:21.900
commonly done in the ICUs and areas in emergency department. And

322
00:21:22.000 --> 00:21:24.400
you can look for various parameters in it which would say whether

323
00:21:24.400 --> 00:21:28.800
the patient is heart's full or heart's empty. Now a full heart

324
00:21:29.400 --> 00:21:34.000
would would show you an increase in the end-diastolic area and the

325
00:21:34.000 --> 00:21:37.200
LV is not completely collapsed. But at the same time if the

326
00:21:37.200 --> 00:21:41.300
LV is kissing, basically if it is completely collapsing, it means the

327
00:21:41.300 --> 00:21:45.100
LV the ventricle can take more volume. The same goes with VTI.

328
00:21:45.100 --> 00:21:49.700
VTI is velocity time integral, but you're putting a pulsatile doppler across

329
00:21:49.700 --> 00:21:54.300
the left ventricular outflow track in a as you're doing a transthoracic

330
00:21:54.300 --> 00:21:58.600
or the deep trunk gastric view in a trans and basically you're

331
00:21:58.600 --> 00:22:03.700
measuring the variability of the VTI based on what maneuver you're

332
00:22:04.300 --> 00:22:08.500
using or what fluid challenge you're giving. So any value when the

333
00:22:08.500 --> 00:22:13.000
value value increases by more than 15% from the previous value depending

334
00:22:13.000 --> 00:22:16.300
upon what fluid challenge you give, it would say or it it

335
00:22:16.300 --> 00:22:20.700
predicts that the patient would need volume and the patient can take

336
00:22:20.700 --> 00:22:25.700
volume. So the value is found to be minimum 15%. But yes,

337
00:22:25.700 --> 00:22:30.200
echo techniques are difficult to perform. You need expertise. Another entity which

338
00:22:30.200 --> 00:22:33.000
is being practiced in the ICUs is carotid VTI. It is similar

339
00:22:33.000 --> 00:22:40.200
to the LBOT VTI wherein you're using the ultrasound you to focus

340
00:22:40.200 --> 00:22:42.900
on the carotid artery and you put a pulsatile doppler and you

341
00:22:42.900 --> 00:22:46.800
see the change in the VTI from the previous value and then

342
00:22:46.800 --> 00:22:50.400
giving a fluid bolus and then see whether the the VTI value

343
00:22:50.400 --> 00:22:53.700
is increasing. So basically it is based on the same principle, but

344
00:22:53.700 --> 00:22:55.900
you're measuring a different area wherein there is a carotid artery. A

345
00:22:55.900 --> 00:22:59.800
lot of studies have come up for carotid VTI and they're found

346
00:22:59.800 --> 00:23:04.800
to be convincing. Focus is something which is exceeding the used and

347
00:23:05.000 --> 00:23:10.300
convincingly used in assessment of fluid in the ICUs and emergency department.

348
00:23:11.800 --> 00:23:15.000
Most important I would say the recent focus is more on the

349
00:23:15.000 --> 00:23:17.900
VAXUS scan. This it's called as the venous excess ultrasound. Now we

350
00:23:17.900 --> 00:23:23.000
all are sort of obsessed with the left heart and right

351
00:23:23.000 --> 00:23:26.400
heart is also equally important whenever we talk about fluid depletion and

352
00:23:26.400 --> 00:23:31.500
fluid replenishment. And so the venous side of circulation since time

353
00:23:31.500 --> 00:23:34.100
immemorial has always been a second fiddle to the arterial side, but

354
00:23:34.100 --> 00:23:38.300
it was champion by a binton at all in 1931 who studied

355
00:23:38.600 --> 00:23:43.000
the impact of venous pressure on the urine output. So when we

356
00:23:43.000 --> 00:23:46.300
talk about perfusion pressure, we what the thing which comes into our

357
00:23:46.300 --> 00:23:48.700
mind is the difference between the mean arterial pressure and the CVP.

358
00:23:48.700 --> 00:23:52.400
But actually it is the pressure difference between the pre-capillary arteriolar and

359
00:23:52.400 --> 00:23:56.700
the post-capillary venular level which actually is at the microcirculatory level which

360
00:23:56.700 --> 00:24:00.000
gives you a measure of the exact true status of the venous

361
00:24:01.000 --> 00:24:05.100
side. So this is potentially being used these days in the ICUs

362
00:24:05.100 --> 00:24:09.700
and it is pretty reliable in assessing the fluid status. Now basic

363
00:24:09.700 --> 00:24:13.600
principle is that you you basically you measuring the IVC first and

364
00:24:13.600 --> 00:24:16.000
if the IVC value is exceeding 2 cm, then you go to

365
00:24:16.000 --> 00:24:18.700
the step two wherein you're seeing the hepatic vein doppler, the portal

366
00:24:18.700 --> 00:24:22.400
vein doppler and the renal vein doppler. Now based upon the severity

367
00:24:22.500 --> 00:24:25.500
or the abnormality what you see in the hepatic vein, the portal

368
00:24:25.500 --> 00:24:28.600
vein and and the renal vein doppler, you grade it basically. So

369
00:24:28.800 --> 00:24:32.600
as the congestion is more, you would find more than two areas

370
00:24:32.800 --> 00:24:36.200
having abnormal patterns. So these are the various patterns you would see

371
00:24:36.200 --> 00:24:38.600
on a doppler profile whenever you perform a hepatic vein or a

372
00:24:38.600 --> 00:24:42.500
portal vein or a renal vein doppler. For example, a portal vein

373
00:24:42.500 --> 00:24:46.300
would lose its monophasic flow and would start become pulsatile when the

374
00:24:46.300 --> 00:24:50.900
fluid status goes bad. And the renal vein doppler also would have

375
00:24:50.900 --> 00:24:55.100
a pulsatile flow from the monophasic flow and to the later stages

376
00:24:55.100 --> 00:25:00.000
when the fluids fluid is patient is too much fluid overloaded, then

377
00:25:00.930 --> 00:25:03.130
It it will only be a diastolic phase what you observe in

378
00:25:03.130 --> 00:25:07.830
the This of course these techniques need training, but it is not

379
00:25:07.830 --> 00:25:13.530
very difficult. Consistent it gives a consistency as far as the

380
00:25:13.630 --> 00:25:17.530
fluid assessment is concerned and it is increasingly being used in the

381
00:25:17.630 --> 00:25:22.330
ICU. The most fascinating and the most common what we look for

382
00:25:22.330 --> 00:25:24.630
in the ultrasound is the pulmonary lines, the A line versus the

383
00:25:24.630 --> 00:25:26.630
B line pattern and this is something which is commonly done in

384
00:25:26.630 --> 00:25:30.930
the ICU. An A line if there is A line in the

385
00:25:30.930 --> 00:25:34.430
lung, it basically suggests that the patient is fluid tolerant and we

386
00:25:34.430 --> 00:25:37.330
can give a bolus to the patient without any risk of pulmonary

387
00:25:37.430 --> 00:25:41.330
edema. But but increasing B lines would say that the patient is

388
00:25:41.330 --> 00:25:45.430
fluid overloaded and you would think 100 times before giving fluid to

389
00:25:45.430 --> 00:25:47.730
that patient, but because in such a scenario you would want to

390
00:25:47.730 --> 00:25:51.530
diurese the patient. Now this these are the various techniques or the

391
00:25:51.530 --> 00:25:55.130
probe positions what you use to divide the lungs in different segments

392
00:25:55.130 --> 00:25:59.630
in the anterior, the lateral and the posterior aspect and do a

393
00:25:59.630 --> 00:26:05.230
longitudinal and transverse scan by using the curvilinear probes. As

394
00:26:05.230 --> 00:26:08.830
I mentioned A lines are normal normal basically you see the A

395
00:26:08.830 --> 00:26:11.730
lines because the ultrasound gets reflected at the pleural line and it

396
00:26:11.730 --> 00:26:15.830
basically creates a reverberation artifact at different levels. Now if this is

397
00:26:15.830 --> 00:26:19.130
lost and you see such comet tail artifacts or lines which are

398
00:26:19.130 --> 00:26:23.730
very you know basically like flashing lines in the lung, it means

399
00:26:23.730 --> 00:26:27.130
the patient's lung is fluid overloaded and that for that patient you

400
00:26:27.130 --> 00:26:30.330
can't give more fluids. So this is a different picture for just

401
00:26:30.330 --> 00:26:34.530
for representation say when you see in a consolidation. Venacaval assessment is

402
00:26:34.530 --> 00:26:38.330
equally important wherein you are looking at the respiratory variation in the

403
00:26:38.330 --> 00:26:42.430
venacaval diameter in a spontaneously breathing patient and a mechanically ventilated patient

404
00:26:42.430 --> 00:26:45.930
which will give you different picture. In a spontaneously breathing patient you

405
00:26:45.930 --> 00:26:49.230
have a negative pleural pressure, so it augments the venous return and

406
00:26:49.230 --> 00:26:53.130
it collapses your IVC. But in a patient who is mechanically ventilated

407
00:26:53.930 --> 00:26:57.530
because of the positive pleural pressure, the RA pressure is increased and

408
00:26:57.530 --> 00:27:01.030
that would lead to a resistance against the venous return. You should

409
00:27:01.030 --> 00:27:05.430
important know that IVC has an extra thoracic course while superior venacava

410
00:27:05.530 --> 00:27:09.330
has an intra thoracic course. So when you see IVC in a

411
00:27:09.330 --> 00:27:12.530
patient who is positively ventilated or the patient who is on mechanical

412
00:27:12.530 --> 00:27:16.630
ventilation, it will distend okay when the when the inspiration happens while

413
00:27:16.630 --> 00:27:21.630
SVC will collapse. So a less intravascular volume would lead

414
00:27:21.630 --> 00:27:26.030
to more variation in the in the parameter between inspiration and expiration.

415
00:27:26.130 --> 00:27:30.830
At the same time if there is a decreased variability between inspiratory

416
00:27:30.830 --> 00:27:34.430
and inspiration and expiration phase when you assess either the SVC or

417
00:27:34.430 --> 00:27:38.130
the IVC, it would mean that the patient cannot get take more

418
00:27:38.130 --> 00:27:40.830
volume. So this is one such picture wherein you are using a

419
00:27:40.830 --> 00:27:45.930
trans thoracic probe or the to high

420
00:27:45.930 --> 00:27:51.330
frequency probe the to you see the patient's IVC assessment

421
00:27:51.630 --> 00:27:53.930
and you put an M mode across it and you look for

422
00:27:53.930 --> 00:27:59.930
the collapsibility during the different phase of respiration. So

423
00:28:00.230 --> 00:28:03.930
if the collapsibility is less than 50% depending upon the length you

424
00:28:03.930 --> 00:28:07.030
grade the IVC and see whether the fluid can be given or

425
00:28:07.130 --> 00:28:12.730
you have to restrict fluid for that patient. IVC

426
00:28:12.730 --> 00:28:15.930
collapsibility index more than 50% is strongly associated with a low CVP

427
00:28:16.230 --> 00:28:20.430
and as I mentioned it is affected by the pattern of respiration

428
00:28:20.430 --> 00:28:25.130
and the RA intra abdominal pressure. In a patient who is positively

429
00:28:25.130 --> 00:28:29.730
ventilated you that there's something called as IVC distensibility index. If it

430
00:28:29.730 --> 00:28:32.730
is more than 12% it predicts an increase in the cardiac index

431
00:28:32.730 --> 00:28:35.030
by at least 15% positive. So it has got a very strong

432
00:28:35.030 --> 00:28:40.430
positive predictive value and the IVC distensibility index more than 18%

433
00:28:40.430 --> 00:28:44.030
is found to be more predictive of increasing the cardiac index by

434
00:28:44.030 --> 00:28:47.630
at least 15% if you are giving a fluid challenge. So these

435
00:28:49.030 --> 00:28:52.530
the measurement of the IVC diameter during the different phases of respiration

436
00:28:52.530 --> 00:28:56.030
are a an important guide in helping you in assessing the fluid

437
00:28:56.030 --> 00:29:01.030
responsiveness in such ventilator patients. So as I mentioned

438
00:29:01.030 --> 00:29:05.730
in mechanical ventilation you would see a distended IVC and a collapsed

439
00:29:05.730 --> 00:29:09.730
IVC in inspiration and expiration respectively. It would be the other way

440
00:29:09.730 --> 00:29:15.930
around in a spontaneously breathing patient. Superior venacaval assessment is

441
00:29:15.930 --> 00:29:19.530
also is in fact more reliable I would say compared to your

442
00:29:19.530 --> 00:29:22.830
IVC assessment in predicting the fluid response and you can use it

443
00:29:22.830 --> 00:29:25.730
by using a trans esophageal probe by using an M mode in

444
00:29:25.730 --> 00:29:29.930
the longitudinal axis in a bi-cable view. SEC collapsibility index more than

445
00:29:29.930 --> 00:29:35.330
60 36% identifies preload responders and which is having a very

446
00:29:35.330 --> 00:29:39.630
high specificity and the why this is more advantageous than an IVC

447
00:29:39.630 --> 00:29:43.330
assessment is because there is very less interference from the intra abdominal

448
00:29:43.430 --> 00:29:47.730
pressure so there are there are studies which shows that SVC variability

449
00:29:47.730 --> 00:29:51.830
is better in predicting the fluid responsiveness compared to your IVC variability.

450
00:29:52.730 --> 00:29:58.830
What does this surviving sepsis campaign say about fluid resuscitation? So initial

451
00:29:58.830 --> 00:30:02.730
resuscitation should always be done with a crystalloid at least 30 ml

452
00:30:02.730 --> 00:30:07.730
per kg within the first 3 hours of resuscitation. And

453
00:30:07.730 --> 00:30:12.130
there have been trials which shows that who are patients in whom

454
00:30:12.130 --> 00:30:15.430
the fluid replenishment was not done adequately within the first 3 hours

455
00:30:15.430 --> 00:30:20.630
of sepsis the odds of increased hospital mortality and the increased length

456
00:30:20.630 --> 00:30:24.830
of stay goes up tremendously. So this was a trial that arise

457
00:30:24.830 --> 00:30:28.530
in the promised trial which actually showed convincing results when the patients

458
00:30:28.530 --> 00:30:33.030
were resuscitated with proper crystalloid at proper volumes of at least 30

459
00:30:33.030 --> 00:30:36.630
ml per kg. And what are you how are you going to

460
00:30:36.630 --> 00:30:41.430
assess the fluid resuscitation? You look for the dynamic parameters as I

461
00:30:41.430 --> 00:30:45.630
mentioned which are more predictive than static parameters. PLR or any stroke

462
00:30:45.630 --> 00:30:49.430
volume variation by SPV or the pulse pressure variation are found to

463
00:30:49.830 --> 00:30:52.930
be more helpful in guiding you in fluid assessment. I will be

464
00:30:52.930 --> 00:30:57.430
touching on those topics in the further slides. Measuring serum lactate is

465
00:30:57.430 --> 00:31:03.130
another important entity whenever you are seeing a response in tissue

466
00:31:03.130 --> 00:31:07.930
hypoxia or dysfunction. Serum lactate is never index of betterment of tissue

467
00:31:07.930 --> 00:31:11.830
perfusion. It is it is clearly clearly clearly told that it it

468
00:31:11.830 --> 00:31:14.630
will give you a better assessment of the tissue hypoxia and tissue

469
00:31:14.630 --> 00:31:19.730
dysfunction. And during acute resuscitation you look

470
00:31:19.730 --> 00:31:22.930
at the serum lactate values also looking at the other parameters, the

471
00:31:22.930 --> 00:31:27.930
clinical context and other other causes possibly see in that patient which

472
00:31:27.930 --> 00:31:32.930
could cause an elevated lactate. Capillary refilling time is very important.

473
00:31:33.730 --> 00:31:37.930
You assess for the capillary refilling time which would you know help

474
00:31:37.930 --> 00:31:42.930
you in giving a status of the

475
00:31:42.930 --> 00:31:46.830
patient's perfusion. Of course along with the other adjunct measures what you

476
00:31:46.830 --> 00:31:52.030
use whenever you are assessing the patient. And the shock study consistently

477
00:31:52.030 --> 00:31:57.330
shown that the capillary refilling time actually assessed patients and then you

478
00:31:57.430 --> 00:32:02.430
give the fluid. They these patient cohort had significantly decreased mortality

479
00:32:02.430 --> 00:32:07.230
and hospital length of stay than in patients wherein you were you

480
00:32:08.530 --> 00:32:13.430
gave fluid without looking at the CRT. Mean arterial pressure of at

481
00:32:13.430 --> 00:32:16.230
least 65 mm of mercury has to be maintained whenever you are

482
00:32:16.430 --> 00:32:21.330
resuscitating a patient with fluids in the ICUs and high targets of

483
00:32:21.330 --> 00:32:25.430
80 to 85 mm of mercury is actually not required. And because

484
00:32:25.630 --> 00:32:28.530
a lot of RCTs have proved that the higher MAP targets actually

485
00:32:28.530 --> 00:32:32.330
did not improve the survival in shock patients. What are the different

486
00:32:32.330 --> 00:32:36.230
methods you use to predict the preload responsiveness? Now I mentioned about

487
00:32:36.230 --> 00:32:39.230
the monitors and the techniques, but what are the various methods you

488
00:32:39.230 --> 00:32:41.930
can use to see whether this patient is responding to the fluid

489
00:32:41.930 --> 00:32:46.730
or not. Now you look for the pulse pressure variation, IVC diameter.

490
00:32:47.030 --> 00:32:50.630
Most commonly used entity is called passive leg raising test and mini

491
00:32:50.630 --> 00:32:54.030
fluid challenge test. So what is passive leg raising test? This is

492
00:32:54.030 --> 00:32:57.630
one of the easiest bedside assessment you can use to see whether

493
00:32:57.630 --> 00:33:01.030
the patient requires fluid or not wherein you are basically putting the

494
00:33:01.030 --> 00:33:05.330
patient in a semi-recumbent position and you are tilting the patient to

495
00:33:05.330 --> 00:33:08.730
an level wherein the the foot end goes up and then you

496
00:33:08.730 --> 00:33:11.430
see the change in the cardiac output or the pulse pressure variation

497
00:33:11.430 --> 00:33:14.830
or the stroke volume variation depending upon what monitoring modality you are

498
00:33:14.830 --> 00:33:18.830
using. Now it is a very easy method and less risky method

499
00:33:18.830 --> 00:33:21.330
because you are just using the patient's own blood volume in the

500
00:33:21.330 --> 00:33:24.330
lower limb and you are not giving any extraneous fluid to see

501
00:33:24.330 --> 00:33:28.430
whether the patient is actually responding to the fluid or not. Now

502
00:33:28.930 --> 00:33:33.130
in conditions wherein the techniques of pulse pressure variability lost the predictability,

503
00:33:33.530 --> 00:33:38.630
the PLR is found to have good predictable response. And there

504
00:33:38.630 --> 00:33:41.730
are studies showing a lot of studies which have come up and

505
00:33:41.830 --> 00:33:44.930
it is something which is used time immemorial and is consistently being

506
00:33:44.930 --> 00:33:48.030
used in the ICUs wherein PLR is known to have a better

507
00:33:48.030 --> 00:33:52.130
predictability and you can safely say whether this patient needs volume or

508
00:33:52.130 --> 00:33:55.830
the this patient doesn't need volume based upon the various parameters. One

509
00:33:55.830 --> 00:33:58.530
such parameter could be the aortic blood flow velocity, the LVO and

510
00:33:58.530 --> 00:34:03.330
VTI or a change in the pulse pressure volume, the stroke volume

511
00:34:03.330 --> 00:34:07.530
variation etc. Mini bolus or a micro bolus challenge can also be

512
00:34:07.530 --> 00:34:10.030
given wherein you are giving a fluid bolus to a patient and

513
00:34:10.030 --> 00:34:13.230
you observe the change in the cardiac output or the change in

514
00:34:13.230 --> 00:34:17.130
the PPV or the SVV or the cardiac index depending upon what

515
00:34:17.130 --> 00:34:20.230
monitor you are using. Okay so whatever whenever there is an increase

516
00:34:20.230 --> 00:34:24.330
in 10% from the baseline value after giving a fluid bolus, it

517
00:34:24.330 --> 00:34:27.830
means that the patient is fluid responsive and you can administer fluid

518
00:34:27.930 --> 00:34:31.730
to that patient. Tidal volume challenge is another entity which is rapidly

519
00:34:31.730 --> 00:34:35.130
being used in the ICUs wherein what you are doing here is

520
00:34:35.430 --> 00:34:38.730
the basic principle is that a patient whenever is being ventilated with

521
00:34:38.730 --> 00:34:43.330
a low tidal volume will not show a fluid response or whenever

522
00:34:43.330 --> 00:34:47.630
you are you know using any modality, any monitors. But incrementally you

523
00:34:47.630 --> 00:34:51.330
increase the tidal volume at that level. The tidal volume can have

524
00:34:51.330 --> 00:34:55.030
its interference on the right ventricle and then the PPV predictability goes

525
00:34:55.030 --> 00:34:59.730
up. So Deveker et al. has proved in a study that PPV

526
00:34:59.730 --> 00:35:02.030
is a reliable predictor if the tidal volume is at least 8

527
00:35:02.030 --> 00:35:05.030
ml per kg. So for example you have a patient in ARDS

528
00:35:05.030 --> 00:35:07.630
and is being ventilated at very low tidal volumes. Any of these

529
00:35:07.630 --> 00:35:10.430
maneuvers will not give a predictable response because the tidal volumes are

530
00:35:10.830 --> 00:35:15.330
very less enough to cause a change in the interference or change

531
00:35:15.330 --> 00:35:18.930
in the value or interfere with the intra thoracic pressure or the

532
00:35:18.930 --> 00:35:22.830
intra pleural pressure and the trans pulmonary pressure. So gradually increase the

533
00:35:22.830 --> 00:35:25.830
tidal volume to see whether it's having an interference and then it

534
00:35:25.830 --> 00:35:28.830
is you know causing fall in the cardiac output. Then you give

535
00:35:28.830 --> 00:35:31.830
a fluid. Basically it is instead of the fluid you are using

536
00:35:31.830 --> 00:35:36.830
a tidal volume as a challenge here. So there are studies

537
00:35:36.830 --> 00:35:41.630
wherein the change in the PPV and SVV obtained by the tidal

538
00:35:41.630 --> 00:35:45.330
volume challenge is found to be more superior to the pulse pressure

539
00:35:45.630 --> 00:35:48.930
PPV and SVV in predicting the fluid responsiveness during low tidal volume

540
00:35:48.930 --> 00:35:53.130
ventilation. So you have a scenario wherein you you are trying to

541
00:35:53.130 --> 00:35:55.730
see the fluid responsiveness in a patient during using a very low

542
00:35:55.730 --> 00:35:58.830
tidal volume. You may not get a positive response and one such

543
00:35:58.830 --> 00:36:01.230
reason could be the low tidal volume at which you are ventilating

544
00:36:01.230 --> 00:36:03.930
this patient. So incrementally you may have to increase the tidal volume

545
00:36:03.930 --> 00:36:09.130
and see the response. Index inspiratory occlusion test is another method

546
00:36:09.330 --> 00:36:13.430
which is practiced wherein what you are doing is basically you stop

547
00:36:13.430 --> 00:36:16.630
the respiration or the ventilation of this patient at the for for

548
00:36:16.630 --> 00:36:22.030
a brief period of 15 seconds and then you see the change

549
00:36:22.030 --> 00:36:26.730
in the LVO T VTI or the cardiac output or the cardiac

550
00:36:26.730 --> 00:36:30.330
index in depending upon the monitor what you are using. So this

551
00:36:30.330 --> 00:36:35.330
is also found to be a reliable predictor for the fluid challenge

552
00:36:35.530 --> 00:36:40.530
in a patient in the ICU. So the

553
00:36:40.530 --> 00:36:44.330
principle here is whenever a patient is on mechanical ventilation each insufflation

554
00:36:44.330 --> 00:36:47.630
that is whenever you are giving a tidal breath during inspiration it

555
00:36:47.630 --> 00:36:50.630
decreases the cardiac preload. So basically you are trying to interrupt this

556
00:36:50.630 --> 00:36:54.630
mechanical ventilation for a few seconds like 15 seconds and this will

557
00:36:54.630 --> 00:36:59.630
lead to you know augmented venous return

558
00:36:59.730 --> 00:37:03.230
and the cardiac preload might transiently increase. So if the cardiac output

559
00:37:03.230 --> 00:37:07.330
increases at the end of this test, it means that the heart

560
00:37:07.330 --> 00:37:10.630
is basically responsive to the fluid and you can consider or you

561
00:37:10.630 --> 00:37:13.830
can think of giving fluid. If it doesn't increase by at least

562
00:37:13.830 --> 00:37:16.530
10 to 15% it means you cannot give more fluid. So these

563
00:37:16.530 --> 00:37:20.130
are various entities by which you can check the fluid responsiveness in

564
00:37:20.130 --> 00:37:24.430
a patient who is being mechanically ventilated in the ICUs. Of course

565
00:37:24.430 --> 00:37:29.630
there are limitations because in ARDS patient you

566
00:37:29.630 --> 00:37:35.430
can't use in a patient who is you know not ventilated. It's

567
00:37:35.430 --> 00:37:40.030
totally out of question and a patient who is you know who

568
00:37:40.030 --> 00:37:43.830
can become hemodynamically unstable. You feel that you know your patient might

569
00:37:43.830 --> 00:37:47.130
become unstable because of the 15 seconds of interruption of the respiration.

570
00:37:47.630 --> 00:37:51.930
Never try these maneuvers. It it can become more dangerous. End-tidal CO2

571
00:37:51.930 --> 00:37:56.230
variation is also something which is used in the ICUs wherein again

572
00:37:57.330 --> 00:38:01.030
an increased cardiac output would cause increased delivery of blood to the

573
00:38:01.130 --> 00:38:04.030
lung and increase the exhale carbon dioxide. So that is the principle.

574
00:38:04.430 --> 00:38:08.930
So you are basically measuring the difference in the ETCO2 with the

575
00:38:09.630 --> 00:38:14.230
fluid and you check whether the ETCO2 is going proportionate to what

576
00:38:14.230 --> 00:38:17.630
amount of fluid I am administering to that patient. Now you can

577
00:38:17.630 --> 00:38:22.630
combine this with other maneuvers. For example a PLR you know you

578
00:38:22.630 --> 00:38:26.630
need not give a fluid. So end-tidal carbon dioxide is one such

579
00:38:26.630 --> 00:38:31.830
entity which we can can be used. But consistency in predicting the

580
00:38:33.430 --> 00:38:38.630
response is not found to be great with end-tidal CO2 based measurement

581
00:38:38.630 --> 00:38:43.630
unlike other parameters. As I mentioned low tidal

582
00:38:43.630 --> 00:38:47.030
volume has patients whenever you're ventilating a patient with a low tidal

583
00:38:47.030 --> 00:38:51.730
volume these patients will have will not show much of a response

584
00:38:51.730 --> 00:38:56.430
to whatever fluid challenge you are giving. And and when airway driving

585
00:38:56.430 --> 00:38:59.130
pressure goes up, for example a patient could be asthmatic, there could

586
00:38:59.130 --> 00:39:02.530
be secretion in the airway, patient could be in heart failure. So

587
00:39:02.530 --> 00:39:07.830
in such conditions these maneuvers pulse pressure variation based techniques, predictability goes

588
00:39:07.830 --> 00:39:10.630
down tremendously. So you should be very careful whenever you're choosing a

589
00:39:10.630 --> 00:39:15.230
patient to whom you're basically you're doing these maneuvers and then you

590
00:39:15.230 --> 00:39:18.730
know using the appropriate fluid challenge techniques. So this is in nutshell

591
00:39:20.630 --> 00:39:24.830
measurement techniques and the fluid challenge techniques what is commonly used across

592
00:39:24.830 --> 00:39:28.430
the world. So PLR is something which is commonly used and it

593
00:39:28.430 --> 00:39:33.430
is found to be done consistent consistent predictor of fluid responsiveness

594
00:39:33.830 --> 00:39:38.330
in a lot of studies based on the pulmonary artery catheter and

595
00:39:38.330 --> 00:39:45.030
the pulse contour analysis. And so is the mini bolus test. End-tidal

596
00:39:45.030 --> 00:39:49.030
occlusion is found to be consistent with the pulmonary artery catheter, but

597
00:39:49.030 --> 00:39:52.330
the reliability goes down with the other parameters or there are very

598
00:39:52.330 --> 00:39:57.730
few studies to say whether the or the monitoring techniques can

599
00:39:57.730 --> 00:40:03.330
show prediction based on index inspiratory occlusion test. So

600
00:40:03.430 --> 00:40:06.130
what are the conditions which may question the reliability of these techniques

601
00:40:06.130 --> 00:40:08.230
what you use to see whether the patient is responding to the

602
00:40:08.230 --> 00:40:12.430
fluid? You have a patient in the ICU who's on norepinephrine. Now

603
00:40:12.430 --> 00:40:16.330
norepinephrine is a pressor. Now a patient who is on high dose

604
00:40:16.330 --> 00:40:21.330
vasopressor or high dose norepinephrine would show an

605
00:40:21.330 --> 00:40:26.430
impaired response whenever you are measuring with any

606
00:40:26.430 --> 00:40:31.430
of these techniques. And the reliability of these dynamic techniques would

607
00:40:31.430 --> 00:40:35.530
go down whenever your patient is on a high dose norepinephrine. And

608
00:40:35.530 --> 00:40:40.230
the same happens whenever the patient is having a right ventricular dysfunction.

609
00:40:41.130 --> 00:40:46.430
It is consistently proven that these techniques of fluid responsiveness, predictability goes

610
00:40:46.430 --> 00:40:49.630
down tremendously when the patient is having an RV dysfunction. An RV

611
00:40:49.630 --> 00:40:53.930
dysfunction is one of the commonest entity in the ICUs and it

612
00:40:53.930 --> 00:40:58.630
is often mismanaged in the ICU and in such an such patient

613
00:40:58.630 --> 00:41:03.130
whatever techniques you are using for a fluid responsiveness won't be able

614
00:41:03.130 --> 00:41:08.530
to predict very well and tell you whether this technique is asking

615
00:41:08.530 --> 00:41:10.830
telling me to give a fluid bolus or not give a fluid

616
00:41:10.830 --> 00:41:13.930
bolus. So you should be very careful when you're doing giving such

617
00:41:13.930 --> 00:41:18.130
maneuvers in RV dysfunction. When the patient is arrhythmic, any arrhythmia for

618
00:41:18.130 --> 00:41:21.930
that matter could be an atrial arrhythmia or a ventricular arrhythmia, any

619
00:41:21.930 --> 00:41:26.830
of these device the predictability goes down tremendously and even it is

620
00:41:26.830 --> 00:41:30.030
found in techniques based on bio reactance and bio impedance like the

621
00:41:30.830 --> 00:41:35.830
or the electrical velocimetry technique. Arrhythmias are found to interfere in

622
00:41:36.330 --> 00:41:42.030
the fluid response prediction. As

623
00:41:42.030 --> 00:41:47.230
I mentioned earlier arrhythmias, spontaneous respiration and a low tidal volume and

624
00:41:47.230 --> 00:41:51.530
any influence on the acute vasomotor status of the patient by a

625
00:41:51.530 --> 00:41:55.930
vasopressor can cause interference in the predictability of any of these techniques.

626
00:41:56.630 --> 00:42:01.830
And airway driving pressures also has been found to cause

627
00:42:01.930 --> 00:42:07.030
a similar effect on the predictability of these techniques. IABP

628
00:42:07.130 --> 00:42:09.130
you know intra aortic balloon pump is something which is commonly used

629
00:42:09.130 --> 00:42:12.030
in the ICUs especially in patients with our own cardiogenic shock or

630
00:42:12.030 --> 00:42:17.530
in a post-operative cardiac patient in with LV dysfunction. Even sheer IABP

631
00:42:17.530 --> 00:42:22.530
patients can interfere with the the the methods

632
00:42:22.530 --> 00:42:25.830
like the pulse pressure variation or the stroke volume variation or even

633
00:42:25.830 --> 00:42:29.230
the bio reactance or the bio impedance based techniques and won't give

634
00:42:29.230 --> 00:42:34.130
you a an accurate assessment of the patient's fluid status. So always

635
00:42:34.130 --> 00:42:39.230
keep in mind the presence of these interfering factors. Also another important

636
00:42:39.230 --> 00:42:43.730
entity being a pulmonary hypertension. Now PAH often coexists with an RV

637
00:42:43.730 --> 00:42:47.430
dysfunction. The predictability of these techniques goes down tremendously. There are a

638
00:42:47.430 --> 00:42:50.530
lot of studies to prove that and especially in cardiac surgical patients

639
00:42:50.530 --> 00:42:55.130
or patients post the pulmonary thromboendarterectomy and patients with PAH and septic

640
00:42:55.130 --> 00:43:00.230
shock as well wherein the predictability of PPV SVV goes down tremendously

641
00:43:00.430 --> 00:43:02.730
and you may not get a clear picture as to the fluid

642
00:43:02.730 --> 00:43:06.230
status. So you should choose the right method to assess the fluid

643
00:43:06.230 --> 00:43:10.430
status in a patient depending upon the condition or the diagnosis or

644
00:43:10.430 --> 00:43:13.930
the coexisting medical illness in such patients. So one formula will not

645
00:43:13.930 --> 00:43:16.330
fit all the patients, one technique will not fit all the patients.

646
00:43:16.330 --> 00:43:18.630
It is not that you do a PLR for one patient. You

647
00:43:18.630 --> 00:43:21.830
can easily do PLR in all the patients. So also look for

648
00:43:21.830 --> 00:43:25.930
the coexisting interfering factors which can give you a false negative value

649
00:43:25.930 --> 00:43:29.230
and you may be in soup if you give a fluid bolus

650
00:43:29.230 --> 00:43:33.330
for such a patient and patient ends up with fluid overload. An

651
00:43:33.330 --> 00:43:38.130
increase lung water, pulmonary compliance goes down. You know these are also

652
00:43:38.130 --> 00:43:43.130
known to increase you know bring down the predictability of any PPV

653
00:43:43.130 --> 00:43:48.530
or the SVV based techniques. To summarize see

654
00:43:49.230 --> 00:43:52.330
IV fluid is something which is an essential thing in any any

655
00:43:52.330 --> 00:43:55.830
patient coming to the hospital. Choosing the right IV fluid is very

656
00:43:55.830 --> 00:43:59.830
important. The content of the IV fluid is the most important. The

657
00:43:59.830 --> 00:44:03.330
amount of the IV fluid is even more crucial. Now you can

658
00:44:03.330 --> 00:44:09.330
you cannot just give an IV fluid to any patient randomly. So

659
00:44:09.330 --> 00:44:12.030
for that you you you you want to see whether the patient

660
00:44:12.030 --> 00:44:15.230
is receptive for that IV fluid based upon the pressure, based upon

661
00:44:15.230 --> 00:44:18.630
the ABG, based upon the clinical examination, based upon the lactate levels,

662
00:44:19.730 --> 00:44:21.430
based up if you have a central line you just look for

663
00:44:21.430 --> 00:44:24.430
the CVP though it is not convincing. You look for the arterial

664
00:44:24.830 --> 00:44:28.530
trace, you look for the variability in the arterial trace. That is

665
00:44:28.530 --> 00:44:31.730
the basics as I mentioned in that stroke volume variation whether it

666
00:44:31.730 --> 00:44:36.130
is there is a swing in the arterial trace. If you have

667
00:44:36.130 --> 00:44:39.430
a point of care machine with you you do an ultrasound, just

668
00:44:39.430 --> 00:44:42.630
look at the IVC, you look at the heart by doing a

669
00:44:42.630 --> 00:44:47.430
trans thoracic echo to see whether the heart is receptive. And use

670
00:44:47.430 --> 00:44:50.530
all the tools what you have. Could be a minimally invasive tool

671
00:44:50.530 --> 00:44:54.730
or a or a non-invasive tool in assessing the fluid responsiveness. Always

672
00:44:54.730 --> 00:44:57.630
bear in mind that one technology is never superior to the other

673
00:44:57.630 --> 00:45:00.430
technology when it comes to fluid assessment. It will just complement your

674
00:45:00.430 --> 00:45:06.230
clinical finding or a clinical examination finding. So without

675
00:45:06.230 --> 00:45:10.130
an assessment tool a blind fluid resuscitation is known to be is

676
00:45:10.130 --> 00:45:13.530
proven to be detrimental. So that is something which always has to

677
00:45:13.530 --> 00:45:17.330
be kept in mind whenever you are administering fluid to a patient.

678
00:45:17.430 --> 00:45:21.530
And as I mentioned all these tools will just complement your general

679
00:45:21.530 --> 00:45:26.430
physical examination and clinical examination. So it's everything put together and try

680
00:45:26.430 --> 00:45:29.630
and you know extracting the best information out of whatever you have

681
00:45:29.630 --> 00:45:34.730
in guiding it helps you in guiding the fluid therapy in choosing

682
00:45:34.730 --> 00:45:38.330
the right fluid and the right amount of fluid for the patient.

683
00:45:38.930 --> 00:45:43.330
Thanks a lot for the patient hearing. Thank you sir. Thank you

684
00:45:43.330 --> 00:45:48.130
so much for such an insightful session sir. Sir we have some

685
00:45:48.130 --> 00:45:51.030
questions from the attendees. Can we move on to the Q and

686
00:45:51.030 --> 00:45:57.930
A? Sir

687
00:45:57.930 --> 00:46:01.330
I'll read the first question I have. Sir is it okay if

688
00:46:01.330 --> 00:46:06.530
I read it out? Sir

689
00:46:06.530 --> 00:46:10.330
the first question is sir how to adjust fluid therapy in patients

690
00:46:10.330 --> 00:46:16.630
with renal impairment? Yeah see

691
00:46:16.830 --> 00:46:21.630
renal impairment patient again as I mentioned you see what is the

692
00:46:21.630 --> 00:46:25.130
fluid status. It could be a using an ultrasound or it could

693
00:46:25.130 --> 00:46:28.930
be a basic pressures and clinical assessment. You have a fluid overloaded

694
00:46:28.930 --> 00:46:34.030
patient who is anuric. The fluid management

695
00:46:34.030 --> 00:46:36.830
is different. Now you'll have to restrict fluid in such patients. It

696
00:46:36.830 --> 00:46:39.230
may be a fluid restriction to less than 1 1.5 L in

697
00:46:39.230 --> 00:46:42.430
24 hours or 1 L in 24 hours depending upon what urine

698
00:46:42.430 --> 00:46:45.230
output the patient is having. And you calculate the insensible loss and

699
00:46:45.230 --> 00:46:47.830
the daily loss and then you adjust. If the patient is making

700
00:46:47.830 --> 00:46:50.330
urine, it depends upon what renal impairment the patient is in. See

701
00:46:50.330 --> 00:46:53.230
renal impairment is a very broad term. Now you have a patient

702
00:46:53.230 --> 00:46:57.030
who is having a pre-renal acute kidney injury. So in such patients

703
00:46:57.030 --> 00:46:59.930
you will have to give fluid because the pre-renal it is the

704
00:46:59.930 --> 00:47:03.330
insult has happened because the patient is hypovolemic. You have a patient

705
00:47:03.330 --> 00:47:06.230
with an intrinsic renal disease with a raised creatinine and the patient

706
00:47:06.230 --> 00:47:10.330
has a history of oliguria. You can't give more fluids to such

707
00:47:10.330 --> 00:47:13.130
patients. Then the patient might end up fluid overloaded and you might

708
00:47:13.130 --> 00:47:16.230
have to dialyze these patients. And you might have a CKD patient

709
00:47:16.230 --> 00:47:20.630
who is on dialysis who is completely fluid restricted say a 1

710
00:47:20.630 --> 00:47:23.430
L per day and you get the patient comes to you. You

711
00:47:23.430 --> 00:47:27.230
can't just overload him with fluid just because he's hypertensive. So there

712
00:47:27.230 --> 00:47:30.030
comes the importance of these point of care techniques. You see the

713
00:47:30.030 --> 00:47:34.430
IVC. See IVC the predictability, the SVC, look at the heart, look

714
00:47:34.430 --> 00:47:37.430
at the clinical condition, look at the ABG, whether the patient is

715
00:47:37.830 --> 00:47:41.730
having increased lactates, whether the patient is acidotic. So based upon these

716
00:47:41.730 --> 00:47:46.030
multiple parameters put together and assessing what renal failure is exactly the

717
00:47:46.030 --> 00:47:51.130
patient having. Renal impairment is a very colloquial broad term. So it's

718
00:47:51.130 --> 00:47:55.830
a pre-renal AKI, the fluid management differs from an intrinsic renal AKI

719
00:47:56.030 --> 00:47:59.330
or a patient with a CKD. CKD who has had a AKI

720
00:47:59.430 --> 00:48:02.830
because of whatever reasons. If you ask me the type of fluid

721
00:48:02.930 --> 00:48:07.430
well there are initially it was like normal saline or the 0.9%

722
00:48:07.430 --> 00:48:12.330
saline was administered. But cavilite or physiological saline can also be administered

723
00:48:12.930 --> 00:48:16.230
depending upon how much urine output is the patient is having and

724
00:48:16.230 --> 00:48:19.030
with a close watch on the potassium levels and the acid-base status

725
00:48:19.030 --> 00:48:24.230
of the patient. Thank you sir. Moving on to the next question.

726
00:48:24.430 --> 00:48:29.430
Good afternoon doctor. How to prevent and manage complications related to central

727
00:48:29.430 --> 00:48:34.430
venous catheter catheterization? So this question is actually

728
00:48:34.430 --> 00:48:37.430
out of context to the present discussion, but still I would want

729
00:48:37.430 --> 00:48:42.530
to cover it. Complications to central venous catheterization are many

730
00:48:43.030 --> 00:48:46.130
that includes complications of the of putting the catheter to managing the

731
00:48:46.130 --> 00:48:51.830
catheter, to infections, to you know bleeding, embolism.

732
00:48:52.230 --> 00:48:55.230
So I think it's a vast topic which can be covered in

733
00:48:55.230 --> 00:48:59.130
a different setup. Yes you have to follow strict hand hygiene protocols

734
00:49:01.030 --> 00:49:04.030
you know whenever you are handling the catheters, whenever you are inserting

735
00:49:04.030 --> 00:49:07.030
the catheter it has to be done in the most sterile way.

736
00:49:07.430 --> 00:49:09.530
Make sure that air is not going in. Make sure that you

737
00:49:09.530 --> 00:49:14.530
use a point of care technique ultrasound in order to avoid avoid

738
00:49:14.530 --> 00:49:17.730
an arterial prick and you are visualizing and inserting it in in

739
00:49:17.730 --> 00:49:21.130
the internal jugular vein or whichever vein you are choosing. We could

740
00:49:21.130 --> 00:49:25.830
be the subclavian vein or the femoral vein. So the prevention is

741
00:49:25.830 --> 00:49:28.730
more important here than managing complications I would say. So you be

742
00:49:28.730 --> 00:49:32.430
smart enough to prevent a complication, anticipate that this might happen and

743
00:49:32.530 --> 00:49:37.030
you try to take precautions and you know what of those complications

744
00:49:37.030 --> 00:49:41.330
which might happen later. But the complications are tremendous. They can be

745
00:49:41.330 --> 00:49:44.630
air embolism, they can be infections, bloodstream infections can happen because of

746
00:49:45.230 --> 00:49:49.230
improper handling of the central venous lines. So in the ICUs I

747
00:49:49.230 --> 00:49:51.830
would say strict hand hygiene protocols are the must. Use hand rubs

748
00:49:53.030 --> 00:49:56.530
before touching the patient, after touching the patient you know follow the

749
00:49:56.530 --> 00:50:00.130
same the this rule everywhere whenever you're doing anything to the patient.

750
00:50:00.400 --> 00:50:03.200
and it's a blanket measure what you have to take whenever you

751
00:50:03.200 --> 00:50:07.900
are handling the central line. But yes, the complications I would I

752
00:50:07.900 --> 00:50:10.500
can discuss it in a different talk I would say. It's not

753
00:50:10.500 --> 00:50:14.800
the right platform to discuss about all the complications. Thank you sir.

754
00:50:15.200 --> 00:50:20.200
Sir next question is indicating indication for lactate levels is

755
00:50:20.200 --> 00:50:25.900
a marker of tissue perfusion in fluid management. Yes,

756
00:50:25.900 --> 00:50:32.500
lactate levels are looked at whenever you are you know looking

757
00:50:32.500 --> 00:50:36.300
at the patient's fluid status and even the surviving sepsis campaign 2021

758
00:50:36.300 --> 00:50:40.200
also has strongly emphasized the same and whenever the lactate levels go

759
00:50:40.200 --> 00:50:43.600
about to you would say the patient depending upon the patient's hemodynamic

760
00:50:43.600 --> 00:50:47.800
status you would want to replenish fluid and seriously look for that

761
00:50:48.400 --> 00:50:51.400
it is not one lactate value which is important it is basically

762
00:50:51.400 --> 00:50:55.400
the correction of the lactate values or the declining values or the

763
00:50:55.400 --> 00:50:59.000
increasing values of lactate you look for. Of course it won't it's

764
00:50:59.000 --> 00:51:04.100
not mandatory that fluid and tissue perfusion only

765
00:51:04.100 --> 00:51:08.600
has to cause an increased lactate value. Lactate values can increase in

766
00:51:08.600 --> 00:51:11.800
infections the lactate value can increase in low cardiac output state. So

767
00:51:11.800 --> 00:51:16.600
lactate is basically a mark of tissue metabolism it's a byproduct and

768
00:51:16.700 --> 00:51:20.000
it could be hypovolemia is one of the many reasons for increase

769
00:51:20.000 --> 00:51:23.400
in lactate levels. So always use this lactate value also with caution

770
00:51:23.400 --> 00:51:26.000
and if you are using it as a marker you follow the

771
00:51:26.000 --> 00:51:28.400
trend in the lactate levels rather than looking at one particular value.

772
00:51:30.700 --> 00:51:35.700
Thank you sir. Sir the last question is sir can you explain

773
00:51:35.700 --> 00:51:40.900
effects of changes in airway resistance on cardiac hemodynamics?

774
00:51:42.000 --> 00:51:48.000
I think this I had emphasized in one slide wherein airway

775
00:51:48.000 --> 00:51:53.200
resistance I would say it the it plays in differently in different

776
00:51:53.200 --> 00:51:55.700
patients that is a patient who is spontaneously breathing and a patient

777
00:51:55.900 --> 00:51:59.500
who is mechanically ventilated. I am presuming that the question is based

778
00:51:59.500 --> 00:52:03.800
on a patient who is intubated. Any increase in the airway resistance

779
00:52:04.000 --> 00:52:07.600
will increase the intrathoracic pressure less I mean it's basically causing a

780
00:52:07.800 --> 00:52:10.200
stack of air beneath the lung and you are not able to

781
00:52:10.200 --> 00:52:13.300
expire that increases the intrathoracic pressure and that will cause a decrease

782
00:52:13.300 --> 00:52:19.000
in the preload. Okay and that can cause hypotension and

783
00:52:19.400 --> 00:52:23.300
as I mentioned see heart and lung behaves like two related entities

784
00:52:23.700 --> 00:52:26.000
from it's like a it's a pump pump in a pump basically.

785
00:52:26.700 --> 00:52:29.900
So any problem with the airways can have detrimental effects on the

786
00:52:29.900 --> 00:52:34.500
right ventricular function more and any problem with the heart can cause

787
00:52:34.600 --> 00:52:39.000
fluid collection in the lung. So it's basically interconnected and if there

788
00:52:39.000 --> 00:52:42.600
is a resistance for for example you have a patient with asthma

789
00:52:43.300 --> 00:52:45.800
suddenly there is a sudden exacerbation of asthma you would see the

790
00:52:45.800 --> 00:52:48.500
peak airway pressure going up on a ventilator. Now because of the

791
00:52:48.500 --> 00:52:52.800
peak airway pressure the the preload can go down and the LV

792
00:52:53.100 --> 00:52:56.100
the RV output can go down because the RV afterload will go

793
00:52:56.100 --> 00:52:59.100
up and there can be hypotension. So there is a direct relationship

794
00:52:59.100 --> 00:53:02.400
between the airway resistance and the cardiac hemodynamics and it should always

795
00:53:02.400 --> 00:53:06.600
be taken care of and look for such increase in the airway

796
00:53:06.600 --> 00:53:12.300
resistance changes whenever you are ventilating a patient in the ICU. Thank

797
00:53:12.300 --> 00:53:17.200
you sir. Sir there has come a clarification to the first question

798
00:53:18.200 --> 00:53:23.300
AKI. AKI

799
00:53:23.300 --> 00:53:25.500
that's what I was asking the AKI what what what sort of

800
00:53:25.500 --> 00:53:28.900
an AKI if it is a pre-renal AKI? Acute kidney injury is

801
00:53:28.900 --> 00:53:32.000
one definition acute kidney injury is not a diagnosis it is basically

802
00:53:32.000 --> 00:53:34.000
you were telling that the creatinine value has gone up by so

803
00:53:34.000 --> 00:53:37.000
and so factor of 0.3 milligrams per deciliter and so much six

804
00:53:37.000 --> 00:53:41.700
hours that's stage one AKI. There are various causes of AKI. So

805
00:53:41.700 --> 00:53:44.400
if it is a pre-renal AKI wherein you have a patient who

806
00:53:44.400 --> 00:53:48.300
is hypertensive for a long time fluid depleted and because of which

807
00:53:48.300 --> 00:53:51.500
the creatinine has gone up there you would try to replenish the

808
00:53:51.500 --> 00:53:56.600
fluid status depending upon the patient's IVC. So here the management is

809
00:53:56.700 --> 00:54:01.400
different. Now you have an acute kidney injury in a patient who

810
00:54:01.400 --> 00:54:04.700
already has an intrinsic renal disease. You have a patient who is

811
00:54:04.700 --> 00:54:07.700
a CKD you are diagnosed with diabetic nephropathy and you have a

812
00:54:08.200 --> 00:54:12.200
creatinine value and you have a history that the patient has been

813
00:54:12.200 --> 00:54:15.900
oliguric for the last one month or so is urine output is

814
00:54:15.900 --> 00:54:18.100
less there you are not going to replenish too much of fluids

815
00:54:19.400 --> 00:54:22.800
and you have another scenario wherein it is a chronic kidney disease

816
00:54:22.800 --> 00:54:28.700
patient who is on dialysis who is absolutely anuric. There

817
00:54:28.900 --> 00:54:34.100
the management differs. So depending upon the type of acute

818
00:54:34.100 --> 00:54:37.800
kidney injury you assess the patient's clinical status that is more important

819
00:54:38.300 --> 00:54:42.300
than managing the AKI. Okay and you see whether the patient's clinical

820
00:54:42.300 --> 00:54:47.700
status warrants a fluid administration whether the patient's focus based techniques show

821
00:54:47.700 --> 00:54:52.300
that the patient's volume status is less and proportionately you give a

822
00:54:52.300 --> 00:54:55.800
fluid challenge and the patient is responding to that fluid challenge by

823
00:54:55.800 --> 00:54:58.700
any of those maneuvers I mentioned in those slides like it could

824
00:54:58.700 --> 00:55:02.000
be a PPV SVV then you give a fluid. It should never

825
00:55:02.000 --> 00:55:06.300
be a blind fluid administration because for example I'll tell you a

826
00:55:06.300 --> 00:55:09.900
scenario a patient with a chronic kidney disease comes to the emergency

827
00:55:10.400 --> 00:55:13.700
CKD patients will most often have an end stage you know they

828
00:55:13.700 --> 00:55:17.600
they may end up having heart disease cardiomyopathy is often seen. So

829
00:55:17.600 --> 00:55:21.000
in such patients with a poor LV you patient is hypertensive you

830
00:55:21.000 --> 00:55:24.000
cannot think of giving fluid to them. The management of the patient

831
00:55:24.000 --> 00:55:27.900
totally differs. So there you need to have a close look at

832
00:55:28.600 --> 00:55:33.900
the volume status the clinical examination the tissue perfusion ABG multiple parameters

833
00:55:33.900 --> 00:55:37.600
you look at IVC there the the patient might need a drug

834
00:55:37.600 --> 00:55:42.000
to augment the cardiac output it it could be a cardiogenic cause

835
00:55:42.000 --> 00:55:47.700
for a hypotension and not a hypovolemic cause. So AKI

836
00:55:48.100 --> 00:55:51.600
what what is the cause for the AKI is most important based

837
00:55:51.600 --> 00:55:56.300
on which the management totally differs. I think the question that answer

838
00:55:56.300 --> 00:55:56.700
is clear.